Part Number Hot Search : 
NVFMCZ OM4215SW G5RAC A3977KED 240901 TN100A ZMM5227B 24FJ64G
Product Description
Full Text Search
 

To Download SG120A-05IG Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  negative fixed voltage regulator description the sg120 series of negative regulators offer self-contained, fixed-voltage capability with up to 1.5a of load current. with a variety of output voltages and four package options this regulator series is an optimum complement to the sg7800a/ 7800/120 line of three terminal regulators. all protective features of thermal shutdown, current limiting, and safe-area control have been designed into these units and since these regulators require only a single output capacitor or a capacitor and 5ma minimum load for satisfactory performance, ease of application is assured. although designed as fixed-voltage regulators, the output voltage can be in- creased through the use of a simple voltage divider. the low quiescent drain current of the device insures good regulation when this method is used, especially for the sg120 series. utilizing an improved bandgap reference design, problems have been eliminated that are normally associated with the zener diode refer- ences, such as drift in output voltage and large changes in the line and load regulation these devices are available in to-257 (hermetically sealed to-220), both isolated and non-isolated), to-3, to-39 and to-66 power packages. features ? ? ? ? ? output current to 1.5a ? ? ? ? ? excellent line and load regulation ? ? ? ? ? foldback current limiting ? ? ? ? ? thermal overload protection ? ? ? ? ? voltages available: -5v, -12v, -15v ? ? ? ? ? voltages not recommended for new designs: -5.2v, -8v, -18v, -20v ? ? ? ? ? contact factory for other voltage options high reliability features - sg120 ? ? ? ? ? available to mil-std - 883 ? ? ? ? ? radiation data available ? ? ? ? ? lmi level "s" processing available sg120 schematic diagram 11/91 rev 1.4 6/97 l in f in ity microelectronics inc. copyright ? 1997 11861 western avenue garden grove, ca 92841 1 (714) 898-8121 fax: (714) 893-2570
sg120 11/91 rev 1.4 6/97 l in f in ity microelectronics inc. copyright ? 1997 11861 western avenue garden grove, ca 92841 2 (714) 898-8121 fax: (714) 893-2570 absolute maximum ratings (note 1) negative regulator -65 c to 150 c 300 c operating junction temperature hermetic (k, r, ig - packages) ................................... storage temperature range ........................... lead temperature (soldering, 10 seconds) ................. figure 1. maximum average power dissipation figure 2. quiescent current vs. load figure 3. temperature coefficient device input voltage differential output voltage input voltage (output shorted to ground) -5v -35v 35v -5.2v -35v 35v -8v -35v 35v -12v -35v 35v -15v -40v 35v -18v -40v 35v -20v -40v 35v 150 c note 1. values beyond which damage may occur. operating junction temperature range: sg120 ........................................................... recommended operating conditions (note 2) characteristic curves -55 c to 150 c note 2. range over which the device is functional. thermal data k package: thermal resistance- junction to case , jc ................. 3.0c/w thermal resistance- junction to ambient , ja ............... 35c/w r package: thermal resistance- junction to case , jc ................. 5.0c/w thermal resistance- junction to ambient , ja .............. 40c/w t package: thermal resistance- junction to case , jc .................. 15c/w thermal resistance- junction to ambient , ja ............ 120c/w ig package: thermal resistance- junction to case , jc ................. 3.5c/w thermal resistance- junction to ambient , ja .............. 42c/w l package: thermal resistance- junction to case , jc .................. 35c/w thermal resistance- junction to ambient , ja ............ 120c/w note a. junction temperature calculation: t j = t a + (p d x ja ). note b. the above numbers for jc are maximums for the limiting thermal resistance of the package in a standard mounting configuration. the ja numbers are meant to be guidelines for the thermal performance of the device/pc-board system. all of the above assume no ambient airflow.
sg120 11/91 rev 1.4 6/97 l in f in ity microelectronics inc. copyright ? 1997 11861 western avenue garden grove, ca 92841 3 (714) 898-8121 fax: (714) 893-2570 negative regulator figure 6. short circuit current vs. v in characteristic curves (continued) figure 4. shortcircuit current vs. v in figure 5. quiescent current vs. v in figure 7. dropout characteristics figure 8. ripple rejection vs. frequency applications figure 9 - fixed output regulator figure 10 - circuit for increasing output voltage note: 1. c1 is required only if regulator is separated from rectifier filter. 2. both c1 and c2 should be low e.s.r. types such as solid tantalum. if aluminum electrolitics are used, at least 10 times values shown should be selected. 3. if large output capacities are used, the regulators must be protected from momentary input shorts. a high current diode from output to input will suffice. note: c3 optional for improved transient response and ripple rejection. r 2 = v(reg) 15ma v out = v (regulator) r 1 + r 2 r 1
sg120 11/91 rev 1.4 6/97 l in f in ity microelectronics inc. copyright ? 1997 11861 western avenue garden grove, ca 92841 4 (714) 898-8121 fax: (714) 893-2570 -5.0v & -5.2v negative regulator electrical characteristics (note 1) sg120-05 (unless otherwise specified, these specifications apply over full operating ambient temperatures for sg120-05 with -55c t a 150c, and v in = -10v, i o = 5ma, c in = 2mf, c out = 1.0mf. low duty cycle pulse testing techniques are used which maintains junction and case temperature equal to the ambient temperature.) units test conditions parameter sg120-5.2 (unless otherwise specified, these specifications apply over full operating ambient temperatures for sg120-5.2 with -55c t a 150c, and v in = -10v, i o = 5ma, c in = 2mf, c out = 1.0mf. low duty cycle pulse testing techniques are used which maintains junction and case temperature equal to the ambient temperature.) units test conditions parameter v mv mv mv v v ma ma ma ma v a a a a db v/v mv c t j = 25c v in = -7v to -25v, t j = 25c power pkgs: i o = 5ma to 1.5a, t j = 25 c t - pkg: i o = 5ma to 500ma, t j = 25 c v in = -7.5v to -25v power pkgs: i o = 5ma to 1.5a, p 20w t - pkg: i o = 5ma to 500ma, p 2w v in = -7v to -25v with line: v in = -7v to -25v, t j = 25c with load: t j = 25c power pkgs: i o = 5ma to 1.5a t - pkg: i o = 5ma to 500ma ? v o = 100mv, t j = 25c power pkgs: i o = 1.0a, t - pkg: i o = 500ma power pkgs: t j = 25c t - pkg: t j = 25c power pkgs: v in = -35v, t j = 25c t - pkg: v in = -35v, t j = 25c ? v in = 10v, f = 120hz, t j = 25c f = 10hz to 100khz (note 2) 1000hrs. at t j = 125c i o = 5ma output voltage line regulation (note 1) load regulation (note 1) total output voltage tolerance quiescent current quiescent current change dropout voltage peak output current short circuit current ripple rejection output noise voltage (rms) long term stability thermal shutdown t j = 25c v in = -7.2v to -25v, t j = 25c power pkgs: i o = 5ma to 1.5a, t j = 25 c t - pkg: i o = 5ma to 500ma, t j = 25 c v in = -7.7v to -25v power pkgs: i o = 5ma to 1.5a, p 20w t - pkg: i o = 5ma to 500ma, p 2w v in = -7.2v to -25v with line: v in = -7.2v to -25v, t j = 25c with load: t j = 25c power pkgs: i o = 5ma to 1.5a t - pkg: i o = 5ma to 500ma ? v o = 100mv, t j = 25c power pkgs: i o = 1.5a, t - pkg: i o = 500ma power pkgs: t j = 25c t - pkg: t j = 25c power pkgs: v in = -35v, t j = 25c t - pkg: v in = -35v, t j = 25c ? v in = 10v, f = 120hz, t j = 25c f = 10hz to 100khz (note 2) 1000hrs. at t j = 125c i o = 5ma output voltage line regulation (note 1) load regulation (note 1) total output voltage tolerance quiescent current quiescent current change dropout voltage peak output current short circuit current ripple rejection output noise voltage (rms) long term stability thermal shutdown note 1. all regulation tests are made at constant junction temperature with low duty cycle testing. 2. this test is guaranteed but is not tested in production. v mv mv mv v v ma ma ma ma v a a a a db v/v mv c min. typ. max. sg120-05 -5.1 25 75 50 -5.2 -5.2 2 0.4 0.4 0.4 2.3 3.3 1.4 1.2 0.6 80 -5.0 10 50 30 -5.0 -5.0 1.1 25 20 175 -4.9 -4.8 -4.8 1.5 0.5 54 min. typ. max. sg120-5.2 -5.1 -5.0 -5.0 1.5 0.5 54 -5.2 15 50 30 -5.2 -5.2 1.1 25 20 175 -5.3 25 75 50 -5.4 -5.4 2 0.4 0.4 0.4 2.3 3.3 1.4 1.2 0.6 80
sg120 11/91 rev 1.4 6/97 l in f in ity microelectronics inc. copyright ? 1997 11861 western avenue garden grove, ca 92841 5 (714) 898-8121 fax: (714) 893-2570 electrical characteristics (note 1) note 1. all regulation tests are made at constant junction temperature with low duty cycle testing. 2. this test is guaranteed but is not tested in production. -8v & -12v negative regulator sg120-08 (unless otherwise specified, these specifications apply over full operating ambient temperatures for sg120-08 with -55c t a 150c, and v in = -14v, i o = 5ma, c in = 1.0mf, c out = 1.0mf. low duty cycle pulse testing techniques are used which maintains junction and case temperature equal to the ambient temperature.) units parameter t j = 25c v in = -10.5v to -25v, t j = 25c power pkgs: i o = 5ma to 1.5a, t j = 25 c t - pkg: i o = 5ma to 500ma, t j = 25 c v in = -10.5v to -25v power pkgs: i o = 5ma to 1.5a, p 20w t - pkg: i o = 5ma to 500ma, p 2w v in = -10.5v to -25v with line: v in = -10.5v to -25v, t j = 25c with load: t j = 25c power pkgs: i o = 5ma to 1.5a t - pkg: i o = 5ma to 500ma ? v o = 100mv, t j = 25c power pkgs: i o = 1.0a, t - pkg: i o = 500ma power pkgs: t j = 25c t - pkg: t j = 25c power pkgs: v in = -35v, t j = 25c t - pkg: v in = -35v, t j = 25c ? v in = 10v, f = 120hz, t j = 25c f = 10hz to 100khz (note 2) 1000hrs. at t j = 125c i o = 5ma sg120-12 (unless otherwise specified, these specifications apply over full operating ambient temperatures for sg120-12 with -55c t a 150c, and v in = -17v, i o = 5ma, c in = 2.0mf, c out = 1.0mf. low duty cycle pulse testing techniques are used which maintains junction and case temperature equal to the ambient temperature.) units test conditions parameter output voltage line regulation (note 1) load regulation (note 1) total output voltage tolerance quiescent current quiescent current change dropout voltage peak output current short circuit current ripple rejection output noise voltage (rms) long term stability thermal shutdown output voltage line regulation (note 1) load regulation (note 1) total output voltage tolerance quiescent current quiescent current change dropout voltage peak output current short circuit current ripple rejection output noise voltage (rms) long term stability thermal shutdown v mv mv mv v v ma ma ma ma v a a a a db v/v mv c v mv mv mv v v ma ma ma ma v a a a a db v/v mv c t j = 25c v in = -14v to -32v, t j = 25c power pkgs: i o = 5ma to 1.0a, t j = 25 c t - pkg: i o = 5ma to 500ma, t j = 25 c v in = -14.5v to -32v power pkgs: i o = 5ma to 1.0a, p 20w t - pkg: i o = 5ma to 500ma, p 2w v in = -14v to -32v with line: v in = -14v to -32v, t j = 25c with load: t j = 25c power pkgs: i o = 5ma to 1.0a t - pkg: i o = 5ma to 500ma ? v o = 100mv, t j = 25c power pkgs: i o = 1.0a, t - pkg: i o = 500ma power pkgs: t j = 25c t - pkg: t j = 25c power pkgs: v in = -35v, t j = 25c t - pkg: v in = -35v, t j = 25c ? v in = 10v, f = 120hz, t j = 25c f = 10hz to 100khz (note 2) 1000hrs. at t j = 125c i o = 5ma typ. max. sg120-8 -7.8 -7.65 -7.65 1.5 0.5 54 -8.0 10 20 10 -8.00 -8.00 1.1 25 32 175 -8.2 25 80 25 -8.35 -8.35 2 0.4 0.4 0.4 2.3 3.3 1.4 1.2 0.6 80 test conditions min. max. sg120-12 -12.3 10 80 25 -12.5 -12.5 4 0.4 0.4 0.4 2.3 3.3 1.4 1.2 0.6 80 min. typ. -11.7 -11.5 -11.5 1.5 0.5 56 -12.0 4 30 10 -12.0 -12.0 2 1.1 25 48 175
sg120 11/91 rev 1.4 6/97 l in f in ity microelectronics inc. copyright ? 1997 11861 western avenue garden grove, ca 92841 6 (714) 898-8121 fax: (714) 893-2570 electrical chartacteristics (note 1) note 1. all regulation tests are made at constant junction temperature with low duty cycle testing. 2. this test is guaranteed but is not tested in production. -15v & -18v negative regulator sg120-15 (unless otherwise specified, these specifications apply over full operating ambient temperatures for sg120-15 with -55c t a 150c, and v in = -20v, i o = 5ma, c in = 2.0mf, c out = 1.0mf. low duty cycle pulse testing techniques are used which maintains junction and case temperature equal to the ambient temperature.) units test conditions parameter sg120-18 (unless otherwise specified, these specifications apply over full operating ambient temperatures for sg120-18 with -55c t a 150c, and v in = -27v, i o = 5ma, c in = 2.0mf, c out = 1.0mf. low duty cycle pulse testing techniques are used which maintains junction and case temperature equal to the ambient temperature.) units test conditions parameter v mv mv mv v v ma ma ma ma v a a a a db v/v mv c t j = 25c v in = -17v to -35v, t j = 25c power pkgs: i o = 5ma to 1.0a, t j = 25 c t - pkg: i o = 5ma to 500ma, t j = 25 c v in = -17.5v to -35v power pkgs: i o = 5ma to 1.0a, p 20w t - pkg: i o = 5ma to 500ma, p 2w v in = -17v to -35v with line: v in = -17v to -35v, t j = 25c with load: t j = 25c power pkgs: i o = 5ma to 1.0a t - pkg: i o = 5ma to 500ma ? v o = 100mv, t j = 25c power pkgs: i o = 1.0a, t - pkg: i o = 500ma power pkgs: t j = 25c t - pkg: t j = 25c power pkgs: v in = -35v, t j = 25c t - pkg: v in = -35v, t j = 25c ? v in = 10v, f = 120hz, t j = 25c f = 10hz to 100khz (note 2) 1000hrs. at t j = 125c i o = 5ma output voltage line regulation (note 1) load regulation (note 1) total output voltage tolerance quiescent current quiescent current change dropout voltage peak output current short circuit current ripple rejection output noise voltage (rms) long term stability thermal shutdown t j = 25c v in = -21v to -33v, t j = 25c power pkgs: i o = 5ma to 1.0a, t j = 25 c t - pkg: i o = 5ma to 500ma, t j = 25 c v in = -22v to -33v power pkgs: i o = 5ma to 1.0a, p 20w t - pkg: i o = 5ma to 500ma, p 2w v in = -21v to -33v with line: v in = -21v to -33v, t j = 25c with load: t j = 25c power pkgs: i o = 5ma to 1.0a t - pkg: i o = 5ma to 500ma ? v o = 100mv, t j = 25c power pkgs: i o = 1.0a, t - pkg: i o = 500ma power pkgs: t j = 25c t - pkg: t j = 25c power pkgs: v in = -35v, t j = 25c t - pkg: v in = -35v, t j = 25c ? v in = 10v, f = 120hz, t j = 25c f = 10hz to 100khz (note 2) 1000hrs. at t j = 125c i o = 5ma output voltage line regulation (note 1) load regulation (note 1) total output voltage tolerance quiescent current quiescent current change dropout voltage peak output current short circuit current ripple rejection output noise voltage (rms) long term stability thermal shutdown v mv mv mv v v ma ma ma ma v a a a a db v/v mv c min. typ. max. sg120-15 -14.7 -14.5 -14.5 1.5 0.5 56 -15.0 5 30 10 -15.0 -15.0 2 1.1 25 60 175 -15.3 10 80 25 -15.5 -15.5 4 0.4 0.4 0.4 2.3 3.3 1.4 1.2 0.6 80 min. typ. max. sg120-18 -17.6 -17.4 -17.4 1.5 0.5 56 -18.0 5 30 10 -18.0 -18.0 2 1.1 25 72 175 -18.4 10 80 25 -18.6 -18.6 4 0.4 0.4 0.4 2.3 3.3 1.4 1.2 0.6
sg120 11/91 rev 1.4 6/97 l in f in ity microelectronics inc. copyright ? 1997 11861 western avenue garden grove, ca 92841 7 (714) 898-8121 fax: (714) 893-2570 electrical chatracteristics (note 1) -20v negative regulator note 1. all regulation tests are made at constant junction temperature with low duty cycle testing. 2. this test is guaranteed but is not tested in production. sg120-20 (unless otherwise specified, these specifications apply over full operating ambient temperatures for sg120-20 with -55c t a 150c, and v in = -29v, i o = 5ma, c in = 2.0mf, c out = 1.0mf. low duty cycle pulse testing techniques are used which maintains junction and case temperature equal to the ambient temperature.) units test conditions parameter t j = 25c v in = -23v to -35v, t j = 25c power pkgs: i o = 5ma to 1.0a, t j = 25 c t - pkg: i o = 5ma to 500ma, t j = 25 c v in = -24v to -35v power pkgs: i o = 5ma to 1.0a, p 20w t - pkg: i o = 5ma to 500ma, p 2w v in = -23v to -35v with line: v in = -23v to -35v, t j = 25c with load: t j = 25c power pkgs: i o = 5ma to 1.0a t - pkg: i o = 5ma to 500ma ? v o = 100mv, t j = 25c power pkgs: i o = 1.0a, t - pkg: i o = 500ma power pkgs: t j = 25c t - pkg: t j = 25c power pkgs: v in = -35v, t j = 25c t - pkg: v in = -35v, t j = 25c ? v in = 10v, f = 120hz, t j = 25c f = 10hz to 100khz (note 2) 1000hrs. at t j = 125c i o = 5ma output voltage line regulation (note 1) load regulation (note 1) total output voltage tolerance quiescent current quiescent current change dropout voltage peak output current short circuit current ripple rejection output noise voltage (rms) long term stability thermal shutdown v mv mv mv v v ma ma ma ma v a a a a db v/v mv c min. typ. max. sg120-20 -20.5 10 80 25 -20.7 -20.7 4 0.4 0.4 0.4 2.3 3.3 1.4 1.2 0.6 80 -20.0 5 30 10 -20.0 -20.0 2 1.1 25 80 175 -19.5 -19.3 -19.3 1.5 0.5 56
sg120 11/91 rev 1.4 6/97 l in f in ity microelectronics inc. copyright ? 1997 11861 western avenue garden grove, ca 92841 8 (714) 898-8121 fax: (714) 893-2570 connection diagrams & ordering information (see notes below) negative regulator part no. package connection diagram 2 1 case is v in 1 2 case is v in ambient temperature range note 1. contact factory for jan and desc product availability. 2. all parts are viewed from the top. 3. "xx" to be replaced by output voltage of specific fixed regulator. 4. some products will be available in leadless chip carrier (lcc) and hermetic flat pack (f). consult factory for price and a vailability v out v out ground ground sg120-xxr/883b -55c to 125c sg120-xxr -55c to 125c 3-terminal to-66 metal can r-package 3-terminal to-3 metal can k-package sg120-xxk/883b -55c to 125c sg120-xxk -55c to 125c v out v in ground 3-pin to-39 metal can t-package sg120-xxt/883b -55c to 125c sg120-xxt -55c to 125c 3 2 v in v out ground 1 case is v in sg120-xxl/883b -55 c to 125 c sg120-xxl -55 c to 125 c 20-pin ceramic (lcc) leadless chip carrier l- package sg120-xxig/883b -55c to 125c sg120-xxig -55c to 125c 3-pin hermetic to-257 ig-package (isolated) (note 4) 1. n.c. 2. v in 3. n.c. 4. v out 5. v out 6. n.c. 7. v out sense 8. n.c. 9. n.c. 10. n.c. 4 5 6 7 8 18 17 16 15 14 9 10 11 12 13 32 12019 11. n.c. 12. n.c. 13. n.c. 14. n.c. 15. gnd 16. n.c. 17. gnd 18. n.c. 19. n.c. 20. v in
?? products?|?applications?|?our focus?|?contact?|?news?|?order? ????site map home ?>? products ?> power?management ?>? negative?fixed?linear?voltage?regulators ?>?SG120A-05IG/883b ? SG120A-05IG/883b???(#44577) ? negative fixed linear voltage regulators division integrated prod (gg) datasheet sg120.pdf mil-spec (none) shipping (none) qual data (none) description key features: " output current to 1.5a " excellent line and load regulation " foldback current limiting " thermal overload protection " voltages available: -5v, -12v, -15v "voltages not recommended for new designs: -5.2v, -8v, -18v, -20v " contact factory for other voltage options the sg120 series of negative regulators offer self-contained, fixed-voltage capability with up to 1.5a of load current. with a variety of output voltages and four package options this regulator series is an optimum complement to the sg7800a/7800/120 line of three terminal regulators. all protective features of thermal shutdown, current limiting, and safe-area control have been designed into these units and since these regulators require only a single output capacitor or a capacitor and 5ma minimum load for satisfactory performance, ease of application is assured. although designed as fixed-voltage regulators, the output voltage can be in-creased through the use of a simple voltage divider. the low quiescent drain current of the device insures good regulation when this method is used, especially for the sg120 series. utilizing an improved bandgap reference design, problems have been eliminated that are normally associated with the zener diode references, such as drift in output voltage and large changes in the line and load regulation these devices are available in to-257 (hermetically sealed to-220), both isolated and non-isolated), to-3, to-39 and to-66 power packages. absolute maximum ratings ?symbol ?max ?unit output current ? i out ?1.5 ?a output voltage ? v out ?-5 ?v differential voltage ??(output shorted to ground) ? v diff ?35 ?v input voltage ? v in ?-35 ?v ? ? ? package to-257_(hermetic)(std) * no drawing available file:///e|/imaging/bitting/cpl/20021014/1014...2_10/msco/10142002_html/SG120A-05IG_883b.htm (1 of 2) [10/22/2002 12:05:31 pm]
? msc 2002, all rights reserved file:///e|/imaging/bitting/cpl/20021014/1014...2_10/msco/10142002_html/SG120A-05IG_883b.htm (2 of 2) [10/22/2002 12:05:31 pm]
?? products?|?applications?|?our focus?|?contact?|?news?|?order? ????site map home ?>? products ?> power?management ?>? negative?fixed?linear?voltage?regulators ?>?SG120A-05IG ? SG120A-05IG???(#44576) ? negative fixed linear voltage regulators division integrated prod (gg) datasheet sg120.pdf mil-spec (none) shipping (none) qual data (none) description key features: " output current to 1.5a " excellent line and load regulation " foldback current limiting " thermal overload protection " voltages available: -5v, -12v, -15v "voltages not recommended for new designs: -5.2v, -8v, -18v, -20v " contact factory for other voltage options the sg120 series of negative regulators offer self-contained, fixed-voltage capability with up to 1.5a of load current. with a variety of output voltages and four package options this regulator series is an optimum complement to the sg7800a/7800/120 line of three terminal regulators. all protective features of thermal shutdown, current limiting, and safe-area control have been designed into these units and since these regulators require only a single output capacitor or a capacitor and 5ma minimum load for satisfactory performance, ease of application is assured. although designed as fixed-voltage regulators, the output voltage can be in-creased through the use of a simple voltage divider. the low quiescent drain current of the device insures good regulation when this method is used, especially for the sg120 series. utilizing an improved bandgap reference design, problems have been eliminated that are normally associated with the zener diode references, such as drift in output voltage and large changes in the line and load regulation these devices are available in to-257 (hermetically sealed to-220), both isolated and non-isolated), to-3, to-39 and to-66 power packages. absolute maximum ratings ?symbol ?max ?unit output current ? i out ?1.5 ?a output voltage ? v out ?-5 ?v differential voltage ??(output shorted to ground) ? v diff ?35 ?v input voltage ? v in ?-35 ?v ? ? ? package to-257_(hermetic)(std) * no drawing available file:///e|/imaging/bitting/cpl/20021014/10142002_10/msco/10142002_html/SG120A-05IG.htm (1 of 2) [10/22/2002 12:05:32 pm]
? msc 2002, all rights reserved file:///e|/imaging/bitting/cpl/20021014/10142002_10/msco/10142002_html/SG120A-05IG.htm (2 of 2) [10/22/2002 12:05:32 pm]
?? products?|?applications?|?our focus?|?contact?|?news?|?order? ????site map home ?>? products ?> power?management ?>? negative?fixed?linear?voltage?regulators ?>?sg120a-08ig ? sg120a-08ig???(#44600) ? negative fixed linear voltage regulators division integrated prod (gg) datasheet sg120.pdf mil-spec (none) shipping (none) qual data (none) description key features: " output current to 1.5a " excellent line and load regulation " foldback current limiting " thermal overload protection " voltages available: -5v, -12v, -15v "voltages not recommended for new designs: -5.2v, -8v, -18v, -20v " contact factory for other voltage options the sg120 series of negative regulators offer self-contained, fixed-voltage capability with up to 1.5a of load current. with a variety of output voltages and four package options this regulator series is an optimum complement to the sg7800a/7800/120 line of three terminal regulators. all protective features of thermal shutdown, current limiting, and safe-area control have been designed into these units and since these regulators require only a single output capacitor or a capacitor and 5ma minimum load for satisfactory performance, ease of application is assured. although designed as fixed-voltage regulators, the output voltage can be in-creased through the use of a simple voltage divider. the low quiescent drain current of the device insures good regulation when this method is used, especially for the sg120 series. utilizing an improved bandgap reference design, problems have been eliminated that are normally associated with the zener diode references, such as drift in output voltage and large changes in the line and load regulation these devices are available in to-257 (hermetically sealed to-220), both isolated and non-isolated), to-3, to-39 and to-66 power packages. absolute maximum ratings ?symbol ?max ?unit output current ? i out ?1.5 ?a output voltage ? v out ?-8 ?v differential voltage ??(output shorted to ground) ? v diff ?35 ?v input voltage ? v in ?-35 ?v ? ? ? package to-257_(hermetic)(std) * no drawing available file:///e|/imaging/bitting/cpl/20021014/10142002_10/msco/10142002_html/sg120a-08ig.html (1 of 2) [10/22/2002 12:05:33 pm]
? msc 2002, all rights reserved file:///e|/imaging/bitting/cpl/20021014/10142002_10/msco/10142002_html/sg120a-08ig.html (2 of 2) [10/22/2002 12:05:33 pm]
?? products?|?applications?|?our focus?|?contact?|?news?|?order? ????site map home ?>? products ?> power?management ?>? negative?fixed?linear?voltage?regulators ?>?sg120a-08ig/883b ? sg120a-08ig/883b???(#44601) ? negative fixed linear voltage regulators division integrated prod (gg) datasheet sg120.pdf mil-spec (none) shipping (none) qual data (none) description key features: " output current to 1.5a " excellent line and load regulation " foldback current limiting " thermal overload protection " voltages available: -5v, -12v, -15v "voltages not recommended for new designs: -5.2v, -8v, -18v, -20v " contact factory for other voltage options the sg120 series of negative regulators offer self-contained, fixed-voltage capability with up to 1.5a of load current. with a variety of output voltages and four package options this regulator series is an optimum complement to the sg7800a/7800/120 line of three terminal regulators. all protective features of thermal shutdown, current limiting, and safe-area control have been designed into these units and since these regulators require only a single output capacitor or a capacitor and 5ma minimum load for satisfactory performance, ease of application is assured. although designed as fixed-voltage regulators, the output voltage can be in-creased through the use of a simple voltage divider. the low quiescent drain current of the device insures good regulation when this method is used, especially for the sg120 series. utilizing an improved bandgap reference design, problems have been eliminated that are normally associated with the zener diode references, such as drift in output voltage and large changes in the line and load regulation these devices are available in to-257 (hermetically sealed to-220), both isolated and non-isolated), to-3, to-39 and to-66 power packages. absolute maximum ratings ?symbol ?max ?unit output current ? i out ?1.5 ?a output voltage ? v out ?-8 ?v differential voltage ??(output shorted to ground) ? v diff ?35 ?v input voltage ? v in ?-35 ?v ? ? ? package to-257_(hermetic)(std) * no drawing available file:///e|/imaging/bitting/cpl/20021014/1014...2_10/msco/10142002_html/sg120a-08ig_883b.htm (1 of 2) [10/22/2002 12:05:34 pm]
? msc 2002, all rights reserved file:///e|/imaging/bitting/cpl/20021014/1014...2_10/msco/10142002_html/sg120a-08ig_883b.htm (2 of 2) [10/22/2002 12:05:34 pm]
?? products?|?applications?|?our focus?|?contact?|?news?|?order? ????site map home ?>? products ?> power?management ?>? negative?fixed?linear?voltage?regulators ?>?sg120a-12ig ? sg120a-12ig???(#44438) ? negative fixed linear voltage regulators division integrated prod (gg) datasheet sg120.pdf mil-spec (none) shipping (none) qual data (none) description key features: " output current to 1.5a " excellent line and load regulation " foldback current limiting " thermal overload protection " voltages available: -5v, -12v, -15v "voltages not recommended for new designs: -5.2v, -8v, -18v, -20v " contact factory for other voltage options the sg120 series of negative regulators offer self-contained, fixed-voltage capability with up to 1.5a of load current. with a variety of output voltages and four package options this regulator series is an optimum complement to the sg7800a/7800/120 line of three terminal regulators. all protective features of thermal shutdown, current limiting, and safe-area control have been designed into these units and since these regulators require only a single output capacitor or a capacitor and 5ma minimum load for satisfactory performance, ease of application is assured. although designed as fixed-voltage regulators, the output voltage can be in-creased through the use of a simple voltage divider. the low quiescent drain current of the device insures good regulation when this method is used, especially for the sg120 series. utilizing an improved bandgap reference design, problems have been eliminated that are normally associated with the zener diode references, such as drift in output voltage and large changes in the line and load regulation these devices are available in to-257 (hermetically sealed to-220), both isolated and non-isolated), to-3, to-39 and to-66 power packages. absolute maximum ratings ?symbol ?max ?unit output current ? i out ?1.5 ?a output voltage ? v out ?-12 ?v differential voltage ??(output shorted to ground) ? v diff ?35 ?v input voltage ? v in ?-35 ?v ? ? ? package to-257_(hermetic)(std) * no drawing available file:///e|/imaging/bitting/cpl/20021014/10142002_10/msco/10142002_html/sg120a-12ig.htm (1 of 2) [10/22/2002 12:05:35 pm]
? msc 2002, all rights reserved file:///e|/imaging/bitting/cpl/20021014/10142002_10/msco/10142002_html/sg120a-12ig.htm (2 of 2) [10/22/2002 12:05:35 pm]
?? products?|?applications?|?our focus?|?contact?|?news?|?order? ????site map home ?>? products ?> power?management ?>? negative?fixed?linear?voltage?regulators ?>?sg120a-12ig/883b ? sg120a-12ig/883b???(#44439) ? negative fixed linear voltage regulators division integrated prod (gg) datasheet sg120.pdf mil-spec (none) shipping (none) qual data (none) description key features: " output current to 1.5a " excellent line and load regulation " foldback current limiting " thermal overload protection " voltages available: -5v, -12v, -15v "voltages not recommended for new designs: -5.2v, -8v, -18v, -20v " contact factory for other voltage options the sg120 series of negative regulators offer self-contained, fixed-voltage capability with up to 1.5a of load current. with a variety of output voltages and four package options this regulator series is an optimum complement to the sg7800a/7800/120 line of three terminal regulators. all protective features of thermal shutdown, current limiting, and safe-area control have been designed into these units and since these regulators require only a single output capacitor or a capacitor and 5ma minimum load for satisfactory performance, ease of application is assured. although designed as fixed-voltage regulators, the output voltage can be in-creased through the use of a simple voltage divider. the low quiescent drain current of the device insures good regulation when this method is used, especially for the sg120 series. utilizing an improved bandgap reference design, problems have been eliminated that are normally associated with the zener diode references, such as drift in output voltage and large changes in the line and load regulation these devices are available in to-257 (hermetically sealed to-220), both isolated and non-isolated), to-3, to-39 and to-66 power packages. absolute maximum ratings ?symbol ?max ?unit output current ? i out ?1.5 ?a output voltage ? v out ?-12 ?v differential voltage ??(output shorted to ground) ? v diff ?35 ?v input voltage ? v in ?-35 ?v ? ? ? package to-257_(hermetic)(std) * no drawing available file:///e|/imaging/bitting/cpl/20021014/1014...2_10/msco/10142002_html/sg120a-12ig_883b.htm (1 of 2) [10/22/2002 12:05:36 pm]
? msc 2002, all rights reserved file:///e|/imaging/bitting/cpl/20021014/1014...2_10/msco/10142002_html/sg120a-12ig_883b.htm (2 of 2) [10/22/2002 12:05:36 pm]
?? products?|?applications?|?our focus?|?contact?|?news?|?order? ????site map home ?>? products ?> power?management ?>? negative?fixed?linear?voltage?regulators ?>?sg120a-15ig ? sg120a-15ig???(#44462) ? negative fixed linear voltage regulators division integrated prod (gg) datasheet sg120.pdf mil-spec (none) shipping (none) qual data (none) description key features: " output current to 1.5a " excellent line and load regulation " foldback current limiting " thermal overload protection " voltages available: -5v, -12v, -15v "voltages not recommended for new designs: -5.2v, -8v, -18v, -20v " contact factory for other voltage options the sg120 series of negative regulators offer self-contained, fixed-voltage capability with up to 1.5a of load current. with a variety of output voltages and four package options this regulator series is an optimum complement to the sg7800a/7800/120 line of three terminal regulators. all protective features of thermal shutdown, current limiting, and safe-area control have been designed into these units and since these regulators require only a single output capacitor or a capacitor and 5ma minimum load for satisfactory performance, ease of application is assured. although designed as fixed-voltage regulators, the output voltage can be in-creased through the use of a simple voltage divider. the low quiescent drain current of the device insures good regulation when this method is used, especially for the sg120 series. utilizing an improved bandgap reference design, problems have been eliminated that are normally associated with the zener diode references, such as drift in output voltage and large changes in the line and load regulation these devices are available in to-257 (hermetically sealed to-220), both isolated and non-isolated), to-3, to-39 and to-66 power packages. absolute maximum ratings ?symbol ?max ?unit output current ? i out ?1.5 ?a output voltage ? v out ?-15 ?v differential voltage ??(output shorted to ground) ? v diff ?35 ?v input voltage ? v in ?-35 ?v ? ? ? package to-257_(hermetic)(std) * no drawing available file:///e|/imaging/bitting/cpl/20021014/10142002_10/msco/10142002_html/sg120a-15ig.htm (1 of 2) [10/22/2002 12:05:38 pm]
? msc 2002, all rights reserved file:///e|/imaging/bitting/cpl/20021014/10142002_10/msco/10142002_html/sg120a-15ig.htm (2 of 2) [10/22/2002 12:05:38 pm]
?? products?|?applications?|?our focus?|?contact?|?news?|?order? ????site map home ?>? products ?> power?management ?>? negative?fixed?linear?voltage?regulators ?>?sg120a-15ig/883b ? sg120a-15ig/883b???(#44463) ? negative fixed linear voltage regulators division integrated prod (gg) datasheet sg120.pdf mil-spec (none) shipping (none) qual data (none) description key features: " output current to 1.5a " excellent line and load regulation " foldback current limiting " thermal overload protection " voltages available: -5v, -12v, -15v "voltages not recommended for new designs: -5.2v, -8v, -18v, -20v " contact factory for other voltage options the sg120 series of negative regulators offer self-contained, fixed-voltage capability with up to 1.5a of load current. with a variety of output voltages and four package options this regulator series is an optimum complement to the sg7800a/7800/120 line of three terminal regulators. all protective features of thermal shutdown, current limiting, and safe-area control have been designed into these units and since these regulators require only a single output capacitor or a capacitor and 5ma minimum load for satisfactory performance, ease of application is assured. although designed as fixed-voltage regulators, the output voltage can be in-creased through the use of a simple voltage divider. the low quiescent drain current of the device insures good regulation when this method is used, especially for the sg120 series. utilizing an improved bandgap reference design, problems have been eliminated that are normally associated with the zener diode references, such as drift in output voltage and large changes in the line and load regulation these devices are available in to-257 (hermetically sealed to-220), both isolated and non-isolated), to-3, to-39 and to-66 power packages. absolute maximum ratings ?symbol ?max ?unit output current ? i out ?1.5 ?a output voltage ? v out ?-15 ?v differential voltage ??(output shorted to ground) ? v diff ?35 ?v input voltage ? v in ?-35 ?v ? ? ? package to-257_(hermetic)(std) * no drawing available file:///e|/imaging/bitting/cpl/20021014/1014...2_10/msco/10142002_html/sg120a-15ig_883b.htm (1 of 2) [10/22/2002 12:05:39 pm]
? msc 2002, all rights reserved file:///e|/imaging/bitting/cpl/20021014/1014...2_10/msco/10142002_html/sg120a-15ig_883b.htm (2 of 2) [10/22/2002 12:05:39 pm]
?? products?|?applications?|?our focus?|?contact?|?news?|?order? ????site map home ?>? products ?> power?management ?>? negative?fixed?linear?voltage?regulators ?>?sg120a-18ig ? sg120a-18ig???(#44486) ? negative fixed linear voltage regulators division integrated prod (gg) datasheet sg120.pdf mil-spec (none) shipping (none) qual data (none) description key features: " output current to 1.5a " excellent line and load regulation " foldback current limiting " thermal overload protection " voltages available: -5v, -12v, -15v "voltages not recommended for new designs: -5.2v, -8v, -18v, -20v " contact factory for other voltage options the sg120 series of negative regulators offer self-contained, fixed-voltage capability with up to 1.5a of load current. with a variety of output voltages and four package options this regulator series is an optimum complement to the sg7800a/7800/120 line of three terminal regulators. all protective features of thermal shutdown, current limiting, and safe-area control have been designed into these units and since these regulators require only a single output capacitor or a capacitor and 5ma minimum load for satisfactory performance, ease of application is assured. although designed as fixed-voltage regulators, the output voltage can be in-creased through the use of a simple voltage divider. the low quiescent drain current of the device insures good regulation when this method is used, especially for the sg120 series. utilizing an improved bandgap reference design, problems have been eliminated that are normally associated with the zener diode references, such as drift in output voltage and large changes in the line and load regulation these devices are available in to-257 (hermetically sealed to-220), both isolated and non-isolated), to-3, to-39 and to-66 power packages. absolute maximum ratings ?symbol ?max ?unit output current ? i out ?1.5 ?a output voltage ? v out ?-18 ?v differential voltage ??(output shorted to ground) ? v diff ?35 ?v input voltage ? v in ?-35 ?v ? ? ? package to-257_(hermetic)(std) * no drawing available file:///e|/imaging/bitting/cpl/20021014/10142002_10/msco/10142002_html/sg120a-18ig.htm (1 of 2) [10/22/2002 12:05:40 pm]
? msc 2002, all rights reserved file:///e|/imaging/bitting/cpl/20021014/10142002_10/msco/10142002_html/sg120a-18ig.htm (2 of 2) [10/22/2002 12:05:40 pm]
?? products?|?applications?|?our focus?|?contact?|?news?|?order? ????site map home ?>? products ?> power?management ?>? negative?fixed?linear?voltage?regulators ?>?sg120a-18ig/883b ? sg120a-18ig/883b???(#44487) ? negative fixed linear voltage regulators division integrated prod (gg) datasheet sg120.pdf mil-spec (none) shipping (none) qual data (none) description key features: " output current to 1.5a " excellent line and load regulation " foldback current limiting " thermal overload protection " voltages available: -5v, -12v, -15v "voltages not recommended for new designs: -5.2v, -8v, -18v, -20v " contact factory for other voltage options the sg120 series of negative regulators offer self-contained, fixed-voltage capability with up to 1.5a of load current. with a variety of output voltages and four package options this regulator series is an optimum complement to the sg7800a/7800/120 line of three terminal regulators. all protective features of thermal shutdown, current limiting, and safe-area control have been designed into these units and since these regulators require only a single output capacitor or a capacitor and 5ma minimum load for satisfactory performance, ease of application is assured. although designed as fixed-voltage regulators, the output voltage can be in-creased through the use of a simple voltage divider. the low quiescent drain current of the device insures good regulation when this method is used, especially for the sg120 series. utilizing an improved bandgap reference design, problems have been eliminated that are normally associated with the zener diode references, such as drift in output voltage and large changes in the line and load regulation these devices are available in to-257 (hermetically sealed to-220), both isolated and non-isolated), to-3, to-39 and to-66 power packages. absolute maximum ratings ?symbol ?max ?unit output current ? i out ?1.5 ?a output voltage ? v out ?-18 ?v differential voltage ??(output shorted to ground) ? v diff ?35 ?v input voltage ? v in ?-35 ?v ? ? ? package to-257_(hermetic)(std) * no drawing available file:///e|/imaging/bitting/cpl/20021014/1014...2_10/msco/10142002_html/sg120a-18ig_883b.htm (1 of 2) [10/22/2002 12:05:41 pm]
? msc 2002, all rights reserved file:///e|/imaging/bitting/cpl/20021014/1014...2_10/msco/10142002_html/sg120a-18ig_883b.htm (2 of 2) [10/22/2002 12:05:41 pm]
?? products?|?applications?|?our focus?|?contact?|?news?|?order? ????site map home ?>? products ?> power?management ?>? negative?fixed?linear?voltage?regulators ?>?sg120a-20ig ? sg120a-20ig???(#44516) ? negative fixed linear voltage regulators division integrated prod (gg) datasheet sg120.pdf mil-spec (none) shipping (none) qual data (none) description key features: " output current to 1.5a " excellent line and load regulation " foldback current limiting " thermal overload protection " voltages available: -5v, -12v, -15v "voltages not recommended for new designs: -5.2v, -8v, -18v, -20v " contact factory for other voltage options the sg120 series of negative regulators offer self-contained, fixed-voltage capability with up to 1.5a of load current. with a variety of output voltages and four package options this regulator series is an optimum complement to the sg7800a/7800/120 line of three terminal regulators. all protective features of thermal shutdown, current limiting, and safe-area control have been designed into these units and since these regulators require only a single output capacitor or a capacitor and 5ma minimum load for satisfactory performance, ease of application is assured. although designed as fixed-voltage regulators, the output voltage can be in-creased through the use of a simple voltage divider. the low quiescent drain current of the device insures good regulation when this method is used, especially for the sg120 series. utilizing an improved bandgap reference design, problems have been eliminated that are normally associated with the zener diode references, such as drift in output voltage and large changes in the line and load regulation these devices are available in to-257 (hermetically sealed to-220), both isolated and non-isolated), to-3, to-39 and to-66 power packages. absolute maximum ratings ?symbol ?max ?unit output current ? i out ?1.5 ?a output voltage ? v out ?-20 ?v differential voltage ??(output shorted to ground) ? v diff ?35 ?v input voltage ? v in ?-35 ?v ? ? ? package to-257_(hermetic)(std) * no drawing available file:///e|/imaging/bitting/cpl/20021014/10142002_10/msco/10142002_html/sg120a-20ig.htm (1 of 2) [10/22/2002 12:05:42 pm]
? msc 2002, all rights reserved file:///e|/imaging/bitting/cpl/20021014/10142002_10/msco/10142002_html/sg120a-20ig.htm (2 of 2) [10/22/2002 12:05:42 pm]
?? products?|?applications?|?our focus?|?contact?|?news?|?order? ????site map home ?>? products ?> power?management ?>? negative?fixed?linear?voltage?regulators ?>?sg120a-20ig/883b ? sg120a-20ig/883b???(#44517) ? negative fixed linear voltage regulators division integrated prod (gg) datasheet sg120.pdf mil-spec (none) shipping (none) qual data (none) description key features: " output current to 1.5a " excellent line and load regulation " foldback current limiting " thermal overload protection " voltages available: -5v, -12v, -15v "voltages not recommended for new designs: -5.2v, -8v, -18v, -20v " contact factory for other voltage options the sg120 series of negative regulators offer self-contained, fixed-voltage capability with up to 1.5a of load current. with a variety of output voltages and four package options this regulator series is an optimum complement to the sg7800a/7800/120 line of three terminal regulators. all protective features of thermal shutdown, current limiting, and safe-area control have been designed into these units and since these regulators require only a single output capacitor or a capacitor and 5ma minimum load for satisfactory performance, ease of application is assured. although designed as fixed-voltage regulators, the output voltage can be in-creased through the use of a simple voltage divider. the low quiescent drain current of the device insures good regulation when this method is used, especially for the sg120 series. utilizing an improved bandgap reference design, problems have been eliminated that are normally associated with the zener diode references, such as drift in output voltage and large changes in the line and load regulation these devices are available in to-257 (hermetically sealed to-220), both isolated and non-isolated), to-3, to-39 and to-66 power packages. absolute maximum ratings ?symbol ?max ?unit output current ? i out ?1.5 ?a output voltage ? v out ?-20 ?v differential voltage ??(output shorted to ground) ? v diff ?35 ?v input voltage ? v in ?-35 ?v ? ? ? package to-257_(hermetic)(std) * no drawing available file:///e|/imaging/bitting/cpl/20021014/1014...2_10/msco/10142002_html/sg120a-20ig_883b.htm (1 of 2) [10/22/2002 12:05:43 pm]
? msc 2002, all rights reserved file:///e|/imaging/bitting/cpl/20021014/1014...2_10/msco/10142002_html/sg120a-20ig_883b.htm (2 of 2) [10/22/2002 12:05:43 pm]
?? products?|?applications?|?our focus?|?contact?|?news?|?order? ????site map home ?>? products ?> power?management ?>? negative?fixed?linear?voltage?regulators ?>?sg120a-5.2ig ? sg120a-5.2ig???(#44546) ? negative fixed linear voltage regulators division integrated prod (gg) datasheet sg120.pdf mil-spec (none) shipping (none) qual data (none) description key features: " output current to 1.5a " excellent line and load regulation " foldback current limiting " thermal overload protection " voltages available: -5v, -12v, -15v "voltages not recommended for new designs: -5.2v, -8v, -18v, -20v " contact factory for other voltage options the sg120 series of negative regulators offer self-contained, fixed-voltage capability with up to 1.5a of load current. with a variety of output voltages and four package options this regulator series is an optimum complement to the sg7800a/7800/120 line of three terminal regulators. all protective features of thermal shutdown, current limiting, and safe-area control have been designed into these units and since these regulators require only a single output capacitor or a capacitor and 5ma minimum load for satisfactory performance, ease of application is assured. although designed as fixed-voltage regulators, the output voltage can be in-creased through the use of a simple voltage divider. the low quiescent drain current of the device insures good regulation when this method is used, especially for the sg120 series. utilizing an improved bandgap reference design, problems have been eliminated that are normally associated with the zener diode references, such as drift in output voltage and large changes in the line and load regulation these devices are available in to-257 (hermetically sealed to-220), both isolated and non-isolated), to-3, to-39 and to-66 power packages. absolute maximum ratings ?symbol ?max ?unit output current ? i out ?1.5 ?a output voltage ? v out ?-5.2 ?v differential voltage ??(output shorted to ground) ? v diff ?35 ?v input voltage ? v in ?-35 ?v ? ? ? package to-257_(hermetic)(std) * no drawing available file:///e|/imaging/bitting/cpl/20021014/10142002_10/msco/10142002_html/sg120a-5.2ig.htm (1 of 2) [10/22/2002 12:05:44 pm]
? msc 2002, all rights reserved file:///e|/imaging/bitting/cpl/20021014/10142002_10/msco/10142002_html/sg120a-5.2ig.htm (2 of 2) [10/22/2002 12:05:44 pm]
?? products?|?applications?|?our focus?|?contact?|?news?|?order? ????site map home ?>? products ?> power?management ?>? negative?fixed?linear?voltage?regulators ?>?sg120a-5.2ig/883b ? sg120a-5.2ig/883b???(#44547) ? negative fixed linear voltage regulators division integrated prod (gg) datasheet sg120.pdf mil-spec (none) shipping (none) qual data (none) description key features: " output current to 1.5a " excellent line and load regulation " foldback current limiting " thermal overload protection " voltages available: -5v, -12v, -15v "voltages not recommended for new designs: -5.2v, -8v, -18v, -20v " contact factory for other voltage options the sg120 series of negative regulators offer self-contained, fixed-voltage capability with up to 1.5a of load current. with a variety of output voltages and four package options this regulator series is an optimum complement to the sg7800a/7800/120 line of three terminal regulators. all protective features of thermal shutdown, current limiting, and safe-area control have been designed into these units and since these regulators require only a single output capacitor or a capacitor and 5ma minimum load for satisfactory performance, ease of application is assured. although designed as fixed-voltage regulators, the output voltage can be in-creased through the use of a simple voltage divider. the low quiescent drain current of the device insures good regulation when this method is used, especially for the sg120 series. utilizing an improved bandgap reference design, problems have been eliminated that are normally associated with the zener diode references, such as drift in output voltage and large changes in the line and load regulation these devices are available in to-257 (hermetically sealed to-220), both isolated and non-isolated), to-3, to-39 and to-66 power packages. absolute maximum ratings ?symbol ?max ?unit output current ? i out ?1.5 ?a output voltage ? v out ?-5.2 ?v differential voltage ??(output shorted to ground) ? v diff ?35 ?v input voltage ? v in ?-35 ?v ? ? ? package to-257_(hermetic)(std) * no drawing available file:///e|/imaging/bitting/cpl/20021014/1014..._10/msco/10142002_html/sg120a-5.2ig_883b.htm (1 of 2) [10/22/2002 12:05:45 pm]
? msc 2002, all rights reserved file:///e|/imaging/bitting/cpl/20021014/1014..._10/msco/10142002_html/sg120a-5.2ig_883b.htm (2 of 2) [10/22/2002 12:05:45 pm]


▲Up To Search▲   

 
Price & Availability of SG120A-05IG

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X